HP Virtual Connect for c-Class BladeSystem Version 3.00 Setup and Installation Guide for HP Integrity BL8x0c i2 Series Server Blades

Installation 46
Module removal and replacement
Beginning with VC v3.00, it is no longer necessary to administratively remove a module if the module is
not in use. If a module is not in use and is physically removed, it is automatically removed from the
domain.
However, if you are removing a module that is in interconnect bay 1 or bay 2 of the primary enclosure,
you must first delete the domain, and then recreate it after the module has been removed.
As a general rule, if a module has been configured and is in use by the domain, this module can only be
replaced with a module of the same type. For example, an HP 1/10Gb-F VC-Enet Module should be
replaced with another HP 1/10Gb-F VC-Enet Module only. However, the following group of modules are
compatible and can be used to replace another module in this list:
HP 4Gb VC FC module
HP VC 4Gb module (with enhanced NPIV)
HP VC 8Gb 20-Port FC module
When replacing a module with a module of another type, do the following:
1. Remove all port assignments.
2. Remove all uplinks and downlinks.
3. Replace the module.
Installing a VC-Enet module
1. Remove the interconnect blank.
NOTE: HP Virtual Connect works optimally in enclosures configured with HP Virtual Connect
interconnect modules only.