HP Virtual Connect for c-Class BladeSystem Version 3.00 Setup and Installation Guide for HP Integrity BL8x0c i2 Series Server Blades

HP Virtual Connect Manager 96
Finish Fibre Channel wizard
When the Fibre Channel Setup Wizard completes, server profiles can be defined and associated with
server blades. Select Define Server Profiles on the home page.
The FC SAN configuration can be changed at any time by using one of the following methods:
Click WWN Settings under Fibre Channel Settings int he left window of the homepage.
Select Fibre Channel Settings from the Configure pull-down menu.
Verifying data center connections
After completing the cabling between the HP BladeSystem c-Class enclosure and the data center
networks, use the following techniques to verify that the network connections are operating properly:
Verify that all external connections are linked and operating at the right speed.
Review the Virtual Connect Manager Network status screens ("Verify network status using VC
Manager" on page 97).
Use port IDs to verify network connections.
Configure a server and verify network connectivity.
Verify link and speed
Verify that all external ports connected to the data center are linked and are operating at the appropriate
speed.
1. Verify that all Virtual Connect Ethernet modules are powered on and functioning properly. The
module status LED should be green for all modules connected and configured in Virtual Connect for
data center use.
If the LED is not green, use the HP Onboard Administrator user interface to diagnose the problem
and verify that the module is powered on.