HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.10/3.15 User Guide

Configuring the Virtual Connect domain using the CLI 120
2
Start with modules in Bays
3-6, create a profile, then
edit the profile and add
connections
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 3
6 Bay 4
7 Bay 5
8 Bay 6
Add connection, 4 times
3
Start with modules in Bays
3 and 4, create a profile,
hotplug modules into Bays
5 and 6, then edit the
profile and add
connections
Port Connected to
1 Bay 3
2 Bay 4
Bay 3 Bay 4
Bay 5 Bay 6
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
Add connection, 2 times
4
Start with modules in Bays
3 and 4, create a profile
(add 2 connections),
hotplug modules into Bays
5 and 6, then edit the
profile
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 3
4 Bay 4
Bay 3 Bay 4
Bay 5 Bay 6
Add connection is
disallowed because the
current FC module
configurations do not
match the existing
connections in the
profile.
This profile will not be
useful after the hotplug.
To resolve this issue,
delete connections 3 and
4, save the profile, and
then scenario 4 applies.
5
Start with modules in Bays
3-6, create a profile,
hotplug modules into Bays
7 and 8, then edit the
profile and add
connections
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 7
6 Bay 8
Add connection, 2 times
6
Start with modules in Bays
3-6, create a profile (add
4 connections), hotplug
modules into Bays 7 and
8, then edit the profile
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 3
6 Bay 4
7 Bay 5
8 Bay 6
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is
disallowed because the
current FC module
configurations do not
match the existing
connections in the
profile.
This profile will not be
useful after the hotplug.
To resolve this issue,
delete connections 5-8,
save the profile, and then
scenario 6 applies.