HP Virtual Connect Version 2.02 Release Notes and Compatibility Matrix
Known issues
General
• For configuration changes, the VC Manager can take up to 90 seconds for the new information to
be saved to non-volatile storage. Configuration information might be lost if power is removed during
this update. A new icon has been added to the Virtual Connect Manager banner line that indicates
a configuration update is in progress or if the backup module has not been updated to the current
configuration changes.
• When updating the VC Manager firmware, the prompt for file downloads to a local system might be
blocked by the browser security setting.
• During an Onboard Administrator failover, VC Manager can lose communication with the Onboard
Administrator for several minutes. During this time, VC Manager is not able to make profile changes
to server blades or perform some enclosure administration functions, such as powering server blades
on and off.
• The OA firmware CLI command update all with VCM Mode causes the VC domain to be lost,
and it must be recovered using OA reset and VCM import of a previous configuration file. This OA
command should not be used if VC Manager is active. This defect has been fixed in OA v2.25, but
could be triggered while upgrading to OA v2.25.
• When operating in a redundant OA environment, after the initial import of the enclosure and
transition to Virtual Connect mode, the standby OA should be reset to ensure proper configuration. If
not reset, a failover to the standby OA results in loss of communication between the Virtual Connect
modules. This problem is resolved in OA releases after OA v2.20.
When operating in a redundant OA environment and the user sends a "Transition Standby to
Active" request to the standby OA, the communication between Virtual Connect Manager and th
active OA might be lost
•
e
. To restore communication, reset the Virtual Connect Manager from the
•
. If
s occurring, the MAC
•
ify the import
•
irtual Connect Manager. If
• RDP "rip and replace" is not supported in a Virtual Connect environment.
Tools pull-down menu.
Replacing the OA in an enclosure containing only one OA causes the OA to leave VC mode. This
mode change requires the VC Manager to re-establish credentials with the OA. During this process,
VC Manager rewrites all server settings and sets the state of the servers to "profile recovered." There
should not be any disruption to the servers, but the administrator should ensure all servers have the
correct MAC addresses and WWNs. Powering off the server clears the "profile recovered" state
any servers are rebooted or power cycled while the credential recovery i
addresses and WWNs might be returned to the factory default settings.
If an enclosure import is attempted with a server blade in a failed state, VC Manager might report
an erroneous error. If the import completes, close the browser and log in again to ver
was successful. The working state of all server blades can be verified using the OA.
Changes in the server RBSU can override Virtual Connect server profile settings for PXE (enabled or
disabled). If a change is made in RBSU, that change is not reflected in V
PXE is set through RBSU, HP recommends using the "Use BIOS" setting.
Known issues 15