HP BladeSystem c-Class Virtual Connect Support Utility Version 1.5.2 Release Notes

Important notes and recommendations 4
Important notes and recommendations
The utility must be run on a client outside of the VC domain being updated. If you run VCSU on a server
blade inside the domain that is being updated, VCSU might lose network connectivity to the VC Ethernet
and Fibre Channel modules, causing unexpected firmware update failures.
IMPORTANT: Do not run VCSU on a server blade inside the VC domain being updated.
For upgrading to VC 3.00 or later, the embedded Virtual Connect GUI and CLI FW update options
have been removed. VCSU is the only stand alone method of FW update.
HP strongly recommends running the healthcheck option on an enclosure before performing any
management tasks. These tasks include, but are not limited to, the following:
o Onboard Administrator firmware upgrade
o Virtual Connect firmware upgrade
o Onboard Administrator planned failover
o Virtual Connect planned failover
When entering an OA user name from a Linux command shell with the domain\username format, use
quotation marks around the username so it is not expanded by the Linux shell.
Example:
vcsu -a collect -i 128.88.142.141 -u "dvt\ldapuser" -p hp123
When entering an OA user password interactively with password masking from a Linux command shell,
use quotation marks around the asterisk so it is not expanded by the Linux shell.
Example:
vcsu -a version -i 192.168.1.100 -u Administrator -p "*"
OA Password :***********