HP Virtual Connect 4.20 Release Notes
Issues and workarounds 6
• When manually removing an external-manager using the VCM CLI, if the Virtual Serial Number range
is not properly specified, the server profile control will not be released from external management.
• When updating VC firmware to 4.10, VCSU activation may abort on other modules after the backup
module is activated. See Customer Advisory c04122651
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
04122651).
• VCM CLI hangs on the show config command when the SNMP read-only community string is
null/blank.
• After upgrading the Virtual Connect firmware to version 4.10 on a VC domain that contains VC Fibre
Channel 8Gb/20 port modules, some of the server blade HBAs may fail to log back into the SAN
fabric. See Customer Advisory c04103189
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
04103189).
• Some Fibre Channel statistics may be invalid on Virtual Connect FlexFabric modules running firmware
version 4.10. See Customer Advisory c04117141
(http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c
04117141).
• Stacking link DAC cables fail after firmware upgrade.
• CLI command reset statistics with encX:Y:* wildcard does not work.
• Cannot "Reset Statistics" from GUI on FlexFabric FC connections.
• Profiles may not display correctly in the VCM Web UI when they are created via VCM CLI and the
SharedServerVlanID is set to false.
• VC-FC 8/24 modules may unexpectedly reboot due to a software fault when an HPUX HPVM is in use
on blades in the same enclosure.
• Browsers can remember the cryptKeyrestore password.
• In HP SIM, when a Managed Report is run against VC-FC modules, the returned description for the
modules appear as NULL or as the serial number of the module.
• The detailed port statistics field cosq[N]_ucast_DroppedPkts incorrectly reports the number of per CoS
queue dropped packets on HP VC FlexFabric 10Gb/24-port Modules and HP VC Flex-10 10Gb Enet
Modules.
• After an enclosure import or recovery, profiles that enter a pending state could encounter an FCoE SAN
outage with FlexFabric 10Gb/24 Port Modules.
Issues and workarounds
Issue
Configbackup restore fails in configuration with Multiple Enclosure after upgrading from VC 2.xx to VC
4.20.
Workaround