HP Virtual Connect for c-Class BladeSystem Version 4.20 User Guide

Virtual Connect networks 113
Not RunningsFlow monitoring is stopped for one of the following reasons:
o There is an internal error.
o The sFlow module IP is not configured.
o CPU usage is high.
DHCP Lease FailedDHCP is enabled for the sFlow module, but an IP address could not be retrieved.
Duplicate IP DetectedA duplicate IP address has been detected.
UnknownVC is unable to determine the state.
sFlow Settings (Ports) screen
Use this screen to select the ports on which to collect sFlow data and to view settings on configured ports.
At least one module and one receiver must be configured to configure associated ports.
To configure an associated port, click Edit in the Action column.
To configure a port for sampling:
1. Select the Configure checkbox under Sampling.
2. Use the pull-down arrow to select the direction: Both, Ingress, or Egress.
3. Enter the Rate (256 to 16777216 packets).
4. Use the pull-down arrow to select a receiver.
To configure a port for polling:
1. Select the Configure checkbox under Polling.
2. Use the arrows to select a polling interval.
3. Use the pull-down arrow to select a receiver.
When you are finished editing the port, click OK.