HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.51/3.60 User Guide
Configuring the Virtual Connect domain using the CLI 146
6
Start with modules in Bays
3–6, create a profile (add
4 connections), hotplug
modules into Bays 7 and
8, then edit the profile.
Port Connected to
1 Bay 3
2 Bay 4
3 Bay 5
4 Bay 6
5 Bay 3
6 Bay 4
7 Bay 5
8 Bay 6
— —
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is
disallowed because the
current FC module
configurations do not
match the existing
connections in the
profile.
This profile is not useful
after the hotplug. To
resolve this issue, delete
connections 5–8, save
the profile, and then
scenario 5 applies.
7
Start with modules in Bays
5 and 6, create a profile,
hotplug modules into Bays
3 and 4, then edit the
profile.
Port Connected to
1 Bay 5
2 Bay 6
— —
Bay 3 Bay 4
Bay 5 Bay 6
— —
Add connection is
disallowed because the
current FC module
configurations do not
match the existing
connections in the
profile.
8
Start with modules in Bays
5–8, create a profile,
hotplug modules into Bays
3 and 4, then edit the
profile.
Port Connected to
1 Bay 5
2 Bay 6
4 Bay 7
5 Bay 8
— —
Bay 3 Bay 4
Bay 5 Bay 6
Bay 7 Bay 8
Add connection is
disallowed because the
current FC module
configurations do not
match the existing
connections in the
profile.
9
Start with FCoE-capable
modules in Bays 1 and 2,
then create a profile and
add connections.
Port Connected to
1 Bay 1
2 Bay 2
Bay 1 Bay 2
— —
— —
— —
Port Connected to
1 Bay 1
2 Bay 2
3 Bay 1
4 Bay 2
5 Bay 1
6 Bay 2
7 Bay 1
8 Bay 2
Add connection, 6 times