VLS9200 user guide (BW402-10009, August 2012)

Table 30 CLI Monitoring Commands (continued)
Usage
1
Command
Returns all the notification alert messages that occurred starting with the specified date.
Where the options are:
-d - mm/dd/yy on or after this date (required)
getNotificationsDate
-h - Displays command usage information (optional)
Deletes the specified notification alerts from the VLS. Where the options are:deleteNotifications
-id <s> - ID number of notification to delete (required)
-h - Displays command usage information (optional)
Specifies an E-mail server with an SMTP gateway to route notification alerts from the
VLS. Where the options are:
-a <s> - E-mail server address (required)
addEmailServer
-c <s> - node IP address (required)
-s <s> - Sender email address (optional)
-h - Displays command usage information (optional)
Returns the E-mail server configuration settings for notification alerts.getEmailServer
Deletes the specified E-mail server from the E-mail notification alerts settings. Where the
options are:
-a <s> - E-mail server address (required)
deleteEmailServer
-c <s> - VLS node IP address (required)
-f - Force - This parameter is ignored and is present only for backward compatibility
(optional)
-h - Displays command usage information (optional)
Adds an E-mail address and desired report formatting to the E-mail notification alert
settings. Where the options are:
-a <s> - E-mail address (required)
addEmail
-c <s> - VLS IP address (required)
-s <n> - Severity (1-Error, 2-Warning, 4-Info, or 8-Unknown) (optional)
-y <n> - E-mail type (1-Long with attachment, 2-Long, 4-Short, or 8-Reports) (optional)
-h - Displays command usage information (optional)
-f <n> - Notification frequency (0-None, 1-Daily, 2-Weekly, 3-Bi-weekly, or 4-Monthly)
(optional)
Returns the report settings for each E-mail address configured for notification alerts.getEmail
Deletes the specified E-mail address from the E-mail notification alert settings. Where the
options are:
-a <s> - E-mail address (required)
deleteEmail
-c <s> - VLS node IP address (required)
-f - Force. This parameter is ignored and is present only for backward compatibility
(optional)
-y <n> - Email type (1-long with attachment, 2-long, 4-short, 8-reports, 16-configuration)
(required)
-h - Displays command usage information (optional)
Specifies an SNMP management console to receive SNMP traps from the VLS. Where
the options are:
-a <s> - SNMP server IP address (required)
addSnmpServer
-c <s> - VLS node IP address (required)
-m <s> - Community (Public, ...) (required)
-v <s> - Trap version (required)
-s <n> - Severity (1-Error, 2-Warning, 4-Info, or 8-Unknown) (required)
170 CLI Command Set