VLS9200 user guide (BW402-10009, August 2012)

Figure 4 VLS9200 Base Enclosure Rear Panel LED Status Normal Operation
LED stateLEDLocationItem
OffVoltage/Fan Fault/Service Required (amber)Power module1
OnInput Source Power Good (green)2
On, if link speed is 2 or 4 GbpsHost 2/4 Gb FC Link Status/Link Activity
(green)
RAID controller3
On, if link speed is 8 GbpsHost 8 Gb FC Link Status/Link Activity (green)4
OnNetwork Port Activity (green)5
OnNetwork Port Link Status (green)6
OffOK to Remove (blue)7
OffUnit Locator (white)8
OnFRU OK (green)9
OffFault/Service Required (amber)10
On, if cache contains unwritten
data
Cache Status (green)11
Off, if cache does not contain
unwritten data
OnExpansion Port Status (green)12
Figure 5 VLS9000 Capacity Enclosure Rear Panel LED Status Normal Operation
LED stateLEDLocationItem
OnAC power good (green)Power module1
OffDC-Fan Fault/Service Required (yellow)2
OnSAS In port status (green)Expansion controller3
OffFault/Service Required (yellow)4
Powering On VLS Arrays 91