HP StoreAll Storage Network Best Practices Guide
Table Of Contents
- HP StoreAll Storage Network Best Practices Guide
- Contents
- 1 Overview of HP StoreAll Storage networking
- 2 StoreAll 9730 platform networking
- 3 StoreAll 93xx/8x00 platform networking
- 4 Expanding an existing cluster
- 5 Support and other resources
- 6 Documentation feedback
- A BOND modes
- B StoreAll 93xx 10 GbE bonding modes and switch interconnection
- C Install and the default Virtual Connect configuration
![](/manual/hp/hp-x9320-10gbe-192tb-network-storage-system/hp-storeall-storage-network-best-practices-guide/images/img-15.png)
Sample ifconfig output for StoreAll node 2:
Figure 5 (page 17) and the corresponding command output illustrate the state of the nodes after
StoreAll node 1 has failed and failover has occurred to StoreAll node 2. The Fusion Manager VIF
(bond0:0) and the StoreAll node 1 User VIF (bond0:2) have both moved to StoreAll node 2.
Figure 5 Node failover example — end state
In Figure 5 (page 17), showing a failed StoreAll node 1 with failover to StoreAll node 2:
• StoreAll node 1 is no longer servicing file client requests.
• StoreAll node 2 is servicing file client requests to 10.30.214.203 (StoreAll node 2–bond0:2).
User VIF failover 17