5.5 HP StorageWorks X9720 Network Storage System Administrator Guide (AW549-96026, March 2011)

Locating firmware
Obtain the firmware by one of the following methods:
HP technical support might send you an updated mxso-firmware RPM. This installs firmware in /
opt/hp/mxso/firmware. This RPM also updates the revision information used by the
exds_stdiag commands. The README.txt file in the directory tells you which file belongs to
which firmware. The files listed in the README.txt file are symlinks to the actual firmware file.
See the following table for a list of the symlinks.
HP technical support might send you a specific firmware file. Install this in the /opt/hp/mxso/
firmware directory.
HP technical support might ask you to download a file from www.hp.com. Install this in the /opt/
hp/mxso/firmware directory.
The following table maps firmware files to components. The actual system details may vary.
Symlink name in /opt/hp/mxso/firmwareComponent
sbdisk_scexeDisk drive
exds9100cx_scexeX9700cx I/O controller
exds9100c_scexe
X9700c (management (SEP) and X9700c
controller firmware)
oa_fwOA firmware
SASsw_scexeSAS switch
SASsw_mp_fwSAS switch management (Solex)
sbdisk_loc_scexeServer blade local disk
Upgrading Onboard Administrator
1. Download the X9720 Network Storage System mxso-firmware RPM. Install the mxso-firm-
ware RPM on all servers.
2. Get the IP address of the Onboard Administrator. For example on a system called glory, look
for an entry called glory-mp in /etc/hosts.
You also need a username and password for the Onboard Administrator. You can use the exds
or Administrator username. The password for the Administrator user is located on a label
on OA 1.
3. Run the following command:
# exds_update_oa_firmware
4. The command prompts for IP address, username and password. Use the data from step 2:
HP Onboard Administrator Firmware Flash Utility v1.0.5
Copyright (c) 2009 Hewlett Packard Development Company, L.P.
OA network address:192.172.1.1
Username:exds
Password:****
Upgrading firmware104