5.5 HP StorageWorks X9720 Network Storage System Administrator Guide (AW549-96026, March 2011)

6. Connect to the switch module that was not replaced:
x123s-ExDS-OA1> connect interconnect <3 or 4>
7. Log in with the same credentials as the OA.
8. Run the following command to prepare for a zonegroup update:
=> sw local forceactive
9. To create the required zoning configuration, run the following commands on the first SAS switch
CLI:
switch local clearupdate
switch local startupdate
switch local zonegroup all delete
switch local advance multi=on
switch local create type=zonegroup zonegroupname=exds_zonegroup
bladeswitchport=31,32,33,34,35,36,37,38,41,42,43,44,45,46,47,48
bladebay 1 add zonegroup=exds_zonegroup
bladebay 2 add zonegroup=exds_zonegroup
bladebay 3 add zonegroup=exds_zonegroup
bladebay 4 add zonegroup=exds_zonegroup
bladebay 5 add zonegroup=exds_zonegroup
bladebay 6 add zonegroup=exds_zonegroup
bladebay 7 add zonegroup=exds_zonegroup
bladebay 8 add zonegroup=exds_zonegroup
bladebay 9 add zonegroup=exds_zonegroup
bladebay 10 add zonegroup=exds_zonegroup
bladebay 11 add zonegroup=exds_zonegroup
bladebay 12 add zonegroup=exds_zonegroup
bladebay 13 add zonegroup=exds_zonegroup
bladebay 14 add zonegroup=exds_zonegroup
bladebay 15 add zonegroup=exds_zonegroup
bladebay 16 add zonegroup=exds_zonegroup
switch local saveupdate
10. Verify that the zonegroups have been updated:
=> sw local zg exds_zonegroup show
Blade Enclosure at x123s-ExDS-ENC
Switch: Local
Zone Group: exds_zonegroup
Zoned Blade Switch Port: 41
Zoned Blade Switch Port: 42
Zoned Blade Switch Port: 43
Zoned Blade Switch Port: 44
Zoned Blade Switch Port: 45
Zoned Blade Switch Port: 46
Zoned Blade Switch Port: 47
Zoned Blade Switch Port: 48
Zoned Blade Switch Port: 31
Zoned Blade Switch Port: 32
Zoned Blade Switch Port: 33
Zoned Blade Switch Port: 34
Zoned Blade Switch Port: 35
Zoned Blade Switch Port: 36
Zoned Blade Switch Port: 37
Zoned Blade Switch Port: 38
Assigned Blade Bay: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16
11. Reconnect the SAS cables.
X9720 Network Storage System Administrator Guide 137