5.5 HP StorageWorks X9720 Network Storage System Administrator Guide (AW549-96026, March 2011)

11. On the node with the active agile management console, expand the distribution tarball or mount
the distribution DVD in a directory of your choice. Expanding the tarball creates a subdirectory
named ibrix that contains the installer program. For example, if you expand the tarball in
nl
/root, the installer is in /root/ibrix.
12. Change to the installer directory if necessary and run the upgrade:
./ibrixupgrade -f
The installer upgrades both the management console software and the file serving node software
on this node.
13. Verify the status of the management console:
/etc/init.d/ibrix_fusionmanager status
The status command confirms whether the correct services are running. Output will be similar to
the following:
Fusion Manager Daemon (pid 18748) running...
Also run the following command, which should report that the console is Active:
<ibrixhome>/bin/ibrix_fm -i
14. Check /usr/local/ibrix/log/fusionserver.log for errors.
15. If the upgrade was successful, failback the file serving node. Run the following command on the
node with the active agile management console:
<ibrixhome>/bin/ibrix_server -f –U -h HOSTNAME
16. From the node on which you failed back the active management console in step 8, change the
status of the management console from maintenance to passive:
<ibrixhome>/bin/ibrix_fm –m passive
17. If the node with the passive management console is also a file serving node, manually fail over
the node from the active management console:
<ibrixhome>/bin/ibrix_server -f –p -h HOSTNAME
Wait a few minutes for the node to reboot, and then run the following command to verify that
the failover was successful. The output should report Up, FailedOver.
<ibrixhome>/bin/ibrix_server -l
18. On the node with the passive agile management console, move the <installer_dir>/ibrix
directory used in the previous release installation to ibrix.old. For example, if you expanded
the tarball in /root during the previous X9000 installation on this node, the installer is in
nl
/root/ibrix.
19. On the node hosting the passive agile management console, expand the distribution tarball or
mount the distribution DVD in a directory of your choice. Expanding the tarball creates a subdir-
ectory named ibrix that contains the installer program. For example, if you expand the tarball
in /root, the installer is in /root/ibrix.
20. Change to the installer directory if necessary and run the upgrade:
./ibrixupgrade -f
The installer upgrades both the management console software and the file serving node software
on the node.
21. Verify the status of the management console:
/etc/init.d/ibrix_fusionmanager status
The status command confirms whether the correct services are running. Output will be similar to
the following:
Fusion Manager Daemon (pid 18748) running...
X9720 Network Storage System Administrator Guide 89