5.5.4 HP X9000 Series Release Notes (TA768-96054, September 2011)

ID>-<FS-ID>.info (for example, Rebalance_29-ibfs1.info). Following is an example
of the log file:
070390:0518545 | <INFO> | 3075611536 | collect counters from segment 3
070391:0520272 | <INFO> | 3075611536 | segment 3 not migrated chunks 1
<this line shows the segment has 1 chunk>
070391:0520285 | <INFO> | 3075611536 | segment 3 not migrated replicas 0 070391:
0520290 | <INFO> | 3075611536 | segment 3 not migrated files 0
070391:0520294 | <INFO> | 3075611536 | segment 3 not migrated directories 0
070391:0520298 | <INFO> | 3075611536 | segment 3 not migrated root 0
070391:0520302 | <INFO> | 3075611536 | segment 3 chunk: inode inum 300000017
(29B3A23C), poid hi64 300000017 (29B3A23C), primary 500000017 <this line
shows information about the chunk>
Run the inum2name command to identify the symbolic name of the chunk file:
root@centos bin]# ./inum2name --fsname=ibfs 500000017
ibfs:/sliced_dir/file3.bin
After obtaining the name of the file, use a command such as cp to move the file manually. Then
run the segment evacuation process again.
Cluster component states
Changes in file serving node status do not appear on the management console until 6 minutes
after an event. During this time, the node status may appear to be UP when it is actually DOWN
or UNKNOWN. Be sure to allow enough time for the management console to be updated before
verifying node status.
Generally, when a vendorstorage component is marked Stale, the component has failed
and is not responding to monitoring. However, if all components are marked Stale, this implies
a failure of the monitoring subsystem. Temporary failures of this system can cause all monitored
components to toggle from Up, to Stale, and back to Up. Common causes of failures in the
monitoring system include:
Reboot of a file-serving node
Network connectivity issues between the management console and a file serving node
Resource exhaustion on a file serving node (CPU, RAM, I/O or network bandwidth)
While network connectivity and resource exhaustion issues should be investigated, they can occur
normally due to heavy workloads. In these cases, you can reduce the frequency at which
vendorstorage components are monitored by using the the following command:
ibrix_fm_tune -S -o vendorStorageHardwareStaleInterval=1800
The default value of this command is 900; the value is in seconds. A higher value reduces the
probably of all components toggling from Up to Stale and back to Up because of the conditions
listed above, but will increase the time before an actual component failure is reported.