HP Storage Platform Storage Provisioning Tool for StoreAll User Guide

Example 36 Parity status
# hpsp_spt -parityStatus
----------------------------------------------------------------------------------------------------
# Name WWN Progress Status Elapsed-Time
----------------------------------------------------------------------------------------------------
1 LUN_C1_P1_V1 6694FC7B26000010B004533457303049 15% JobStateRunning 13 mins 52 secs
2 LUN_C1_P2_V1 6A013F7C26000010B005533457303049 15% JobStateRunning 13 mins 47 secs
3 LUN_C1_P3_V1 6056957C26000010B006533457303049 15% JobStateRunning 13 mins 41 secs
4 LUN_C1_P4_V1 674CEF7C26000010B007533457303049 15% JobStateRunning 13 mins 35 secs
----------------------------------------------------------------------------------------------------
4 volumes have parity initialization process running
Reconfiguring spares
Syntax
hpsp_spt -rs
hpsp_spt --reconfigureSpares
Description
Reconfigures the spares of all existing volumes based on the known configuration determined by
the storage profile.
Example 37 Reconfigure spares
# hpsp_spt -rs
Using profile: x9730_BalCap_Raid6-2T for spare reconfiguration
...................
Successfully reconfigured the spares with profile: x9730_BalCap_Raid6-2T
Fixing the names of volumes and pools
Syntax
hpsp_spt -fixNames
hpsp_spt --fn
Description
Fixes the names of volumes and pools to ensure that there are no duplicate names. It also ensures
that new names adhere to the naming convention.
Example 38 Fix names
# hpsp_spt -fixNames
Operation completed successfully