6.1.5 HP StoreAll Storage Release Notes (AW549-96064, April 2013)

The default value of this command is 900; the value is in seconds. A higher value reduces the
probability of all components toggling from Up to Stale and back to Up because of the conditions
listed above, but will increase the time before an actual component failure is reported.
SNMP
When the IBRIX SNMP agent is configured, do not restart snmpd. If the snmpd restart command
is run on the active node, you will need to take one of these steps:
If Phone Home was configured, reconfigure it.
If Phone Home was not configured, reconfigure the IBRIX SNMP agent.
HP Insight Remote Support
After HP Insight Remote Support is configured, do not restart snmpd. See “SNMP” (page 18) for
more information.
In certain cases, large number of error messages such as the following appear in /var/log/
hp-snmp-agents/cma.log:
Feb 08 13:05:54 x946s1 cmahostd[25579]: cmahostd: Can't update OS
filesys object: /ifs1 (PEER3023)
This error message occurs because the file system exceeds <n> TB. (This situation will be corrected
in a future release.) To disable logging, edit the script /opt/hp/hp-snmp-agents/server/
etc/cmahostd and remove the option -l <logname>. Then restart the agents using service
hp-snmp-agents restart.
If you want to keep logging enabled, be aware that the log messages occur frequently, and you
will need to monitor and clean up the log file regularly to avoid filling the file system.
If Fully Qualified Domain Name (FQDN) resolution is not configured properly for the hosts, the
following error appears when hpsmhd is restarted:
Could not reliably determine the server's fully qualified domain name,
using <ip> for ServerName
To configure FQDN resolution, use either the /etc/hosts file or the Domain Name Service.
If SNMP is logging excessively, add the following command to the file /etc/sysconfig/
snmpd.options to stop the logging:
OPTIONS="-LS 0-4 d -Lf /dev/null -p /var/run/snmpd.pid -a"
To enable the default SNMP logging, add a pound sign (#) to the following command in the file
/etc/sysconfig/snmpd.options and save the file:
# OPTIONS="-LS 0-4 d -Lf /dev/null -p /var/run/snmpd.pid -a"
Then restart the SNMP service:
service snmpd restart
On X9320/X9720 systems, the virtual SAS manager and VC connect manager must be configured
manually for HP Support.
On HP SIM 7.1, X9320/X9300 nodes are discovered as “HP X9320 NetStor FSN” if MSA
storage is registered on the cluster nodes. This does not affect sending alerts to HP Support.
18 Workarounds