6.3 HP StoreAll Storage Release Notes (TA768-96086, April 2013)

NOTE: This pass through connection to the integrated I/O console is provided for
convenience and does not supply additional access control. For security reasons, use the
password features of the integrated switch.
The following is an example of command’s output:
Connecting to integrated switch 3 at 115200,N81...
Escape character is '<Ctrl>_' (Control + Shift + Underscore)
Press [Enter] to display the switch console:
-----------------------------------------------------------------------------
WARNING: This is a private system. Do not attempt to login unless you are an
authorized user. Any authorized or unauthorized access and use may be moni-
tored and can result in criminal or civil prosecution under applicable law.
-----------------------------------------------------------------------------
VSM-0025B3D4AD5D login: exds
Password:
HP Virtual SAS Manager CLI 2.2-17.0 (SEP 1 FW 2.82) (SEP 2 FW 2.82
6. Once the prompt is given, reset the SAS switch by entering the following command.
sw local reset hardware forced
The following is an example of the command’s output from a 9730:
[2013-Jan-29 11:06:39] Hardware reset on Switch 5, Scope: Local switch only.
Performing hard reset
7. Retry the operation (discovery/flash recommendation/flash) that previously failed.
8. After the switch reboots and displays the login prompt, press the following keys in order:
1. Press the RETURN key.
2. Press the tilde (~) key.
3. Press the period (.) key.
Firmware update alert events are cleared every 24 hours. Ignore the alert for the next 24 hours
if you updated the firmware in response to an alert.
The HTTP WebDAV share might not let you create a file or folder. It displays the following message:
You dont have permission to do this action.
Workaround: Remount the WebDAV share by entering the following command:
net use * http://192.168.1.1/smita/
In this instance, the HTTP WebDAV share is 192.168.1.1/smita.
During an upgrade from 6.1 to 6.2.1 or later, if there is I/O work load on a file serving node,
the HP-SMB services might not start itself after upgrade. This could make the SMB share not
accessible from that node. To recover from this situation, restart the HP-SMB services after upgrade
if there is a share access issue after upgrade.
If clients previously mapped an SMB share using the hostname/FQDN, they will be prompted
continuously to enter their credentials when attempting to access the SMB share after the upgrade.
(The share can be accessed successfully using the IP address.) To workaround this situation, disjoin
and then rejoin all file serving nodes to the Active Directory domain. This can be done using the
GUI or the ibrix_auth command.
After upgrading the StoreAll operating system, the segment evacuation task might fail with the
message Completed with error. This could occur in a rare situation when the file system
only has two segments and both the source and destination segments contain the file and its
replica. To resolve this issue, add another segment and restart the evacuation process.
Workarounds 9