6.2 HP IBRIX 9000 Storage Network Best Practices Guide (TA768-96069, December 2012)

Table 13 IBRIX 9730 mapping for two additional physical user networks (continued)
Connection Type
VC External
ConnectionVC Module
FSN Physical
Interface
Allocated
Bandwidth
FSN
InterfaceNetwork
Primary External
Connection
X4Interconnect Bay 1eth 43.5 GbBond2User2
LACP trunking with X3X3
Primary External
Connection
X4Interconnect Bay 2eth 5
LACP trunking with X3X3
Primary External
Connection
X5Interconnect Bay 1eth 63.5 GbBond3User3
Primary External
Connection
X5Interconnect Bay 2eth 7
Physical cabling
Figure 19 IBRIX 9730 one additional physical user network minimum cabling
The minimum cabling required to attach an IBRIX 9730 enclosure with one additional physical
user network consists of the eight patch cables shown in Figure 19. For maximum redundancy,
each patch cable ideally connects to a physically separate edge switch in the customer network.
50 IBRIX 9730 platform networking