6.2 HP IBRIX 9000 Storage Network Best Practices Guide (TA768-96069, December 2012)

Table 19 IBRIX 93xx unified network configuration cabling summary (continued)
DestinationOriginConnection
Customer Edge Switch User/Cluster
subnet
Rear of Server 2, Expansion slot, eth
5 SFP connector
Server 2, Datapath 2
Customer Edge Switch Management
subnet
Rear of Server 1, Built-in iLO RJ-45
connector
Server 2, iLO
Customer Edge Switch Management
subnet
Rear of MSA enclosure, Upper
controller slot, Integrated RJ-45
connector
MSA enclosure, Controller A
Customer Edge Switch Management
subnet
Rear of MSA enclosure, Lower
controller slot, Integrated RJ-45
connector
MSA enclosure, Controller B
Verifying the network configuration
Run the following command to verify and troubleshoot the unified network configuration.
Verify FSN network interface devices. Use the ifconfig command to summarize the available
network interfaces, configured bond interfaces, and active VIFs.
NOTE: In a dual 10 Gb NIC configuration, slave eth 6 and slave eth 7 are present in ifconfig.
Unified network 61