6.0 HP X9720 Network Storage System Administrator Guide (AW549-96034, December 2011)

hba PAPWV0F9SXA00S P700m in 7930RFCC
fw 5.74
boxes 0 disks 0 luns 0
batteries 0/- cache -
switch HP.3G.SAS.BL.SWH in 4A fw 2.72
switch HP.3G.SAS.BL.SWH in 3A fw 2.72
switch HP.3G.SAS.BL.SWH in 4B fw 2.72
switch HP.3G.SAS.BL.SWH in 3B fw 2.72
ctlr P89A40A9SV600X ExDS9100cc in 01/USP7030EKR slot 1
fw 0126.2008120502
boxes 3 disks 80 luns 10
batteries 2/OK cache OK
box 1 ExDS9100c sn USP7030EKR fw 1.56 temp OK fans OK,OK,OK,OK power OK,OK
box 2 ExDS9100cx sn CN881502JE fw 1.28 temp OK fans OK,OK power OK,OK,OK,OK
box 3 ExDS9100cx sn CN881502JE fw 1.28 temp OK fans OK,OK power OK,OK,OK,OK
ctlr P89A40A9SUS0LC ExDS9100cc in 01/USP7030EKR slot 2
fw 0126.2008120502
boxes 3 disks 80 luns 10
batteries 2/OK cache OK
box 1 ExDS9100c sn USP7030EKR fw 1.56 temp OK fans OK,OK,OK,OK power OK,OK
box 2 ExDS9100cx sn CN881502JE fw 1.28 temp OK fans OK,OK power OK,OK,OK,OK
box 3 ExDS9100cx sn CN881502JE fw 1.28 temp OK fans OK,OK power OK,OK,OK,OK
Analysis:
disk problems on USP7030EKR
* box 3 drive [10,15] missing or failed
ctlr firmware problems on USP7030EKR
* 0126.2008120502 (min 0130.2009092901) on ctlr P89A40A9SV600
Network testing tools
You can use the following tools to test the network:
exds_netdiag—Performs miscellaneous testing of networks in an HP Blade environment
exds_netperf—Isolates performance issues
exds_netdiag
The exds_netdiag utility performs tests on and retrieves data from the networking components
in an X9720 Network Storage System. It performs the following functions:
Reports failed Ethernet Interconnects (failed as reported by the HP Blade Chassis Onboard
Administrator)
Reports missing, failed, or degraded site uplinks
Reports missing or failed NICs in server blades
Useful utilities and processes 113