6.3 HP StoreAll Storage Installation Guide (TA768-96085, April 2013)

Downloading and installing the InfiniBand software
HP supports Mellanox OFED 1.5.3 for use with 9300/9320 systems. To download the software,
go to:
http://h20311.www2.hp.com/hpc/us/en/infiniband-matrix.html
Locate the HCA you have installed and click Firmware/Software. Select your version of Red Hat
Enterprise Linux 5 Server, and then download the appropriate Mellanox InfiniBand Driver.
Install OFED 1.5.3 on each file serving node, following the installation instructions provided with
the software.
NOTE: Review the release notes for general limitations and known issues with OFED 1.5.3.
Installing the driver
To install the driver, complete the following steps:
1. Install the IB OFFED stack without 32-bit and without ib-bonding. Run the following command:
mlnxofedinstall --without-32bit - -without-ib-bonding
2. Check the affected kernel files.
/lib/modules/2.6.18-194.el5/updates/kernel/net/sunrpc/sunrpc.ko
/lib/modules/2.6.18-194.el5/updates/kernel/fs/nfsd/nfsd.ko
/lib/modules/2.6.18-194.el5/updates/kernel/fs/nfs/nfs.ko
/lib/modules/2.6.18-194.el5/updates/kernel/fs/lockd/lockd.ko
/lib/modules/2.6.18-194.el5/updates/kernel/fs/nfs_common/nfs_acl.ko
Downloading and installing the InfiniBand software 141