HP Storage Platform Firmware Management Tool for StoreAll User Guide

Table 25 CLI exit status codes (continued)
DescriptionExit codeOperation
A firmware update was not attempted for any components.0Perform update operation
The firmware of all targeted components was updated successfully.1
The firmware of all targeted components was updated successfully and a
reboot is required.
2
The firmware of all targeted components was updated successfully and a
coordinated server reboot is required.
3
Error—Failed to update the firmware of one or more components.4
Obtaining help
Syntax
# hpsp_fmt -help
Description
Displays the help message. This message is mostly a mnemonic aid for the various options and
parameters for the subcommands.
Displaying the FMT version
Syntax
# hpsp_fmt -V
Description
Displays a string in the format <major number>.<minor number>.<build version> on
the console.
Example 1 Display of FMT version number
# hpsp_fmt -v
HP Storage Platform Firmware Management Tool
Version 2.00.12830
Obtaining help 19