HP Storage Platform Firmware Management Tool for StoreAll User Guide

Example 15 Firmware update of the embedded network adapter on 8800/8200 platforms
# hpsp_fmt -f -c NIC
Flashing NIC: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>
----------------------------------------------------------------------------------------------------
Device :NIC
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Embedded Network Adapter using CP018942.scexe.
The system must be restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
NIC HP Embedded Network Adapter Yes Success (Reboot Pending)
----------------------------------------------------------------------------------------------------
At this stage, you can optionally reboot the server to activate the updated firmware or wait for
other firmware updates, if any, and perform a reboot once for them all.
Power management controller
Example 16 Firmware update of the power management controller on 8800/8200 platforms
# hpsp_fmt f c Power_Mgmt_Ctlr --force
You have provided force option which will rewrite or downgrade the firmware
Do you want to proceed (Y/N)?y
Flashing Power_Mgmt_Ctlr: Based on the configuration, it may take 5 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :Power_Mgmt_Ctlr
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for Power Management Controller
using CP013163.scexe. The system must be
restarted to complete the operation.
Reboot Required :Yes
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Power_Mgmt_Ctlr Power Management Controller Yes Success (Reboot Pending)
--------------------------------------------------------------------------------
At this stage, you can optionally reboot the server to activate the updated firmware or wait for
other firmware updates, if any, and perform a reboot once for them all.
Embedded smart array controller
Example 17 Firmware update of the embedded smart array controller on 8800/8200 platforms
# hpsp_fmt -f -c Smart_Array_Ctlr
Flashing Smart_Array_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>
Device :Smart_Array_Ctlr
Status :Success (Reboot Pending)
Code :0x1001
CONDITIONAL_SUCCESS :Flash succeeded for HP Embedded Smart Array Controller using
CP021158.scexe. The system must be restarted to complete the
operation.
Reboot Required :Yes
Updating firmware 29