HP Storage Platform Firmware Management Tool for StoreAll User Guide

Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
Smart_Array_Ctlr HP Embedded Smart Array Yes Success (Reboot Pending)
Controller
----------------------------------------------------------------------------------------------------
At this stage, you can optionally reboot the server to activate the updated firmware or wait for
other firmware updates, if any, and perform a reboot once for them all.
Storage controller
CAUTION: To avoid failure, ensure the following prerequisites are met before performing a
firmware update operation on the storage controller:
High availability (if present) is disabled for this node.
All data services, including file system services, are stopped.
Do not cycle power or restart devices during the firmware update.
When upgrading the storage controllers in the 8800 couplet using the command to upgrade the
storage controller only, complete the upgrade as follows:
1. Fail over to node 2. See “Failing a server over manually” in the Administrator Guide for your
platform.
2. On node 1, run the -f -c Storage_Ctlr command as shown in the following example.
Example 18 Firmware update of 8800 storage controllers
# hpsp_fmt -f -c Storage_Ctlr
Flashing Storage_Ctlr: Based on the configuration, it may take 10 minutes.
<<< Succeeded >>>
Device :Storage_Ctlr
Status :Success (Reboot Pending)
Code :0x1003
CONDITIONAL_SUCCESS :Flash succeeded for HP SAS Storage Controller using Defender212_Invader_
2013111801_opt.bin. This system and, subsequently, its peer system needs
to be restarted in order to complete the operation.
See documentation for more information.
Reboot Required :Yes
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
Storage_Ctlr HP SAS Storage Yes Success (Reboot Pending)
Controller
----------------------------------------------------------------------------------------------------
3. Reboot node 1 and wait for it to completely power up.
4. Fail over to node 1. See “Failing a server over manually” in the Administrator Guide for your
platform.
5. Reboot node 2, which will automatically copy the firmware to controllers on the node. Wait
for the node to completely power up.
6. Fail back to node 2. See “Failing back a server” in the Administrator Guide for your platform.
If you have to downgrade the firmware on the storage controller, complete the following steps:
1. On node 1, run hpsp_fmt f c Storage_Ctlr.
30 StoreAll 8800 and 8200 FMT command reference and examples