HP Storage Platform Firmware Management Tool for StoreAll User Guide

Example 20 Firmware update of the storage enclosure I/O module on the 8800 platform
# hpsp_fmt -f -c Enclosure_IO_Mod
Flashing Enclosure_IO_Mod: Based on the configuration, it may take 30 minutes.
<<< Not attempted >>>
Flashing Enclosure_IO_Mod: Based on the configuration, it may take 60 minutes.
<<< Succeeded >>>
----------------------------------------------------------------------------------------------------
Device :Enclosure_IO_Mod
Status :Flash Not Attempted
Code :0x1030
INFORMATION :Flash not attempted for HP Storage Enclosure IO Module using
CAMSPR0147_6G_app_4MB_ai.pmc: firmware is up to rev - to force the
install use the option '--force'.
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
Device :Enclosure_IO_Mod
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for HP Storage Enclosure IO Module using C-704.fuf
Reboot Required :No
Coordinated Reboot Required :No
----------------------------------------------------------------------------------------------------
SUMMARY:
----------------------------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
----------------------------------------------------------------------------------------------------
Enclosure_IO_Mod HP Storage Enclosure No Flash Not Attempted
IO Module
Enclosure_IO_Mod HP Storage Enclosure No Success
IO Module
----------------------------------------------------------------------------------------------------
Storage enclosure hard disk drives
CAUTION: The prerequisite measures to be followed before performing firmware update operation
on enclosure HDDs:
Storage disk drive update is an OFFLINE process. All host and array I/O must be stopped
prior to the update.
To avoid spurious failure indications and potential system crashes, you must suspend hardware
monitoring during the update process. You should execute hpspmonControl --pause on
both servers in the couplet before performing the flash operation. You should then make sure
to execute hpspmonControl --resume on both servers in the couplet after the flash
operation is complete.
Do not cycle power or restart devices during a firmware update
Ensure that the storage system configuration is not being reconfigured during a firmware
update.
Ensure that no other user is performing administrative functions on the storage system.
Ensure that all file systems on the storage controller are unmounted. Failure to comply may
result in the operating system failing.
To update the firmware on the storage enclosure hard disk drives:
1. Update the firmware (as shown in Example 21 (page 34)) on node 1.
2. When the update has completed successfully, power off node 2.
3. Reboot node 1.
4. Power on node 2.
Example 21 Firmware update of the storage enclosure hard disk drives on the 8800 platform
# hpsp_fmt -f -c Enclosure_HDD
Please read through the following WARNING messages before continuing with the updates:
34 StoreAll 8800 and 8200 FMT command reference and examples