HP Storage Platform Firmware Management Tool for StoreAll User Guide

Virtual connect module
Example 41 Firmware update of the virtual connect module on 9730 and X9720 platforms
# hpsp_fmt -f -c VC_Flex-10 -cs --ignorerole
Flashing VC_Flex-10: Based on the configuration, it may take 40 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :VC_Flex-10
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for HP VC Flex-10 Enet Module
using vcfwall360.bin
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
VC_Flex-10 HP VC Flex-10 Enet Module No Success
--------------------------------------------------------------------------------
SAS switch
X9720 platform
CAUTION: The 3Gb SAS switch flash update is an OFFLINE process so as to avoid potential
data unavailability issues.
Take care of the following prerequisite measures before performing a firmware update operation
on a 3G SAS switch:
Ensure that all I/O is halted.
Unmount the file systems on on all the servers in this C7000 enclosure.
Example 42 Firmware update of a flashing SAS switch on an X9720 platform
# hpsp_fmt -f -c 3Gb_SAS_BL_SW -cs
Please read through the following WARNING messages before continuing with the updates:
***WARNING***
- SAS switch flash is an OFFLINE process.
- To avoid potential data un-availability issues,
- ensure that all I/Os are halted
- un-mount the file-systems on all the servers in this C7000 enclosure.
Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y
Do you want to proceed (Y/N)?y
Flashing 3Gb_SAS_BL_SW: Based on the configuration, it may take 80 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :SAS_SWITCH_BAY_3
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for SAS_SWITCH_BAY_3 using
S-2_2_17_0.img
Reboot Required :No
Coordinated Reboot Required :No
Device :SAS_SWITCH_BAY_4
Status :Success
Code :0x1000
50 StoreAll 9730 and IBRIX X9720 FMT command reference and examples