HP Storage Platform Firmware Management Tool for StoreAll User Guide

SAS_SWITCH_BAY_7 HP 6Gb SAS BL Switch No Success
SAS_SWITCH_BAY_8 HP 6Gb SAS BL Switch No Success
--------------------------------------------------------------------------------
IBRIX X9720 storage components
This section contains example updates of the following:
“SAS storage controller (ExDS9100cc)” (page 52)
“Storage enclosure I/O module” (page 53)
“Storage enclosure hard disk drives” (page 54)
SAS storage controller (ExDS9100cc)
CAUTION: Take care of the following prerequisite measures before performing a firmware update
operation on a SAS storage controller:
Perform the storage controller update OFFLINE if the active version is less than 1.30.
Ensure that all host and array I/O is stopped prior to the update.
Do not interrupt the setup while the firmware is being updated. Ensure that the storage system
configuration is not being reconfigured during the firmware update.
Ensure that no other user is performing administrative functions on the storage system.
Ensure that all file systems on the storage controller are unmounted. Failure to comply may
result in the operating system failing.
Example 44 Firmware update of the SAS storage controller (ExDS9100cc) on the X9720 platform
# hpsp_fmt -f -c storage_ctlr
Storage controller update is performed OFFLINE if active version is lesser than 1.30.
Please read through the following WARNING messages before continuing with the OFFLINE updates:
***WARNING***
- Ensure that all host and array I/O must be stopped prior to the update.
- Do not interrupt the setup while firmware is getting updated.
- Ensure that the storage system configuration is not being reconfigured during firmware update.
- Ensure that no other user is performing administrative functions on the storage system.
- Make sure all the filesystems are unmounted. Failure to comply may result in an OS crashing.
Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y
Do you want to proceed (Y/N)?y
Flashing Storage_Ctlr: Based on the configuration, it may take 15 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :Storage_Ctlr
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for HP SAS Storage Controller
using CP017800.scexe
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Storage_Ctlr HP SAS Storage Controller No Success
--------------------------------------------------------------------------------