HP Storage Platform Firmware Management Tool for StoreAll User Guide

“Storage enclosure hard disk drives ” (page 75)
All storage components” (page 77)
SAS storage controller
CAUTION: Take care of the following prerequisite measures before performing a firmware update
operation on a SAS Storage controller:
To avoid spurious failure indications and potential system crashes, you must suspend hardware
monitoring during the update process. You should execute hpspmonControl --pause on
both servers in the couplet before performing the flash operation. You should then make sure
to execute hpspmonControl --resume on both servers in the couplet after the flash
operation is complete.
Do not cycle power or restart devices during a firmware update.
Ensure that the storage system configuration is not being reconfigured during a firmware
update.
Ensure that redundant paths to all storage enclosure HDDs exist.
The command output in Example 67 (page 72) lists the measures to be taken before the update
operation.
NOTE: For the StoreAll 9320 G7 platform, the firmware image for the HP P2000 storage controller
is a bundle that consists of firmware images of compatible enclosure I/O modules. Therefore, as
part of the P2000 storage controller firmware update operation, the compatible enclosure I/O
modules that need UPGRADE also get updated.
Example 67 Firmware update of the SAS storage controller (ExDS9100cc) on 9320/9300 platforms
# hpsp_fmt -fr -c storage_ctlr -ci 10.20.12.111 -cu <user> -cp <password>
Based on the configuration, Flash recommendation may take 4 minutes.
<<< Completed >>>
# hpsp_fmt -f -c storage_ctlr -ci 10.20.12.111 -cu <user> -cp <password>
Please read through the following WARNING messages before continuing with the updates:
***WARNING***
- To avoid spurious failure indications and potential system crashes, you must suspend hardware monitoring
during the update process. You should execute "hpspmonControl --pause" on both servers in the couplet before
performing the flash operation. You should then make sure to execute "hpspmonControl --resume" on both
servers
in the couplet after the flash operation is complete.
- Do not cycle power or restart devices during a firmware update.
- Ensure that the storage system configuration is not being reconfigured during a firmware update.
- Ensure that redundant paths to storage enclosure HDD exists.
Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y
Do you want to proceed (Y/N)?y
INFORMATION: As part of storage controller flash, all the compatible io-modules
would also get flashed if needed
Flashing Storage_Ctlr: Based on the configuration, it may take 90 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :Storage_Ctlr
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for HP SAS Storage Controller
using CP017994.scexe
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
72 StoreAll 9320 and 9300 FMT command reference and examples