HP Storage Platform Firmware Management Tool for StoreAll User Guide

Example 68 Firmware update of the storage enclosure I/O module on 9320/9300 platforms
# hpsp_fmt -fr -c enclosure_io_mod -ci 10.20.12.111 -cu <user> -cp <password>
Based on the configuration, Flash recommendation may take 20 minutes.
<<< Completed >>>
# hpsp_fmt -f -c enclosure_io_mod -ci 10.20.12.111 -cu <user> -cp <password>
Please read through the following WARNING messages before continuing with the updates:
***WARNING***
- To avoid spurious failure indications and potential system crashes, you must suspend hardware monitoring
during the update process. You should execute "hpspmonControl --pause" on both servers in the couplet before
performing the flash operation. You should then make sure to execute "hpspmonControl --resume" on both
servers
in the couplet after the flash operation is complete.
- Do not cycle power or restart devices during a firmware update.
- Ensure that the storage system configuration is not being reconfigured during a firmware update.
Please confirm you have read all the above warning messages and taken necessary actions (Y/N)?y
Do you want to proceed (Y/N)?y
Flashing Enclosure_IO_Mod: Based on the configuration, it may take 60 minutes.
<<< Not attempted >>>
Flashing Enclosure_IO_Mod: Based on the configuration, it may take 60 minutes.
<<< Succeeded >>>
--------------------------------------------------------------------------------
Device :Enclosure_IO_Mod
Status :Flash Not Attempted
Code :0x1060
INFORMATION :Flash not attempted for HP Storage Enclosure IO
Module : Storage controller enclosure IO
module(s) can only be flashed as part of storage
controller firmware flash operation. Please run
the flash operation for storage controller.
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
Device :Enclosure_IO_Mod
Status :Success
Code :0x1000
SUCCESS :Flash succeeded for HP Storage Enclosure IO
Module using CP017789.scexe
Reboot Required :No
Coordinated Reboot Required :No
--------------------------------------------------------------------------------
SUMMARY:
--------------------------------------------------------------------------------
Device Description Reboot Flash Status
Reqd.
--------------------------------------------------------------------------------
Enclosure_IO_Mod HP Storage Enclosure IO No Flash Not Attempted
Module
Enclosure_IO_Mod HP Storage Enclosure IO No Success
Module
--------------------------------------------------------------------------------
74 StoreAll 9320 and 9300 FMT command reference and examples