HP Storage Platform Firmware Management Tool for StoreAll User Guide

7 Troubleshooting
General tool failures
Platform string from Repository is null or empty, exiting
Related error messages:
0x1A01: Firmware recipe file /etc/opt/hp/platform/firmware/Repository.xml does not exist.
0x1A02: Firmware recipe file /etc/opt/hp/platform/firmware/Repository.xml is not readable.
0x1A03: Error processing firmware recipe file /etc/opt/hp/platform/firmware/Repository.xml -
please check the file is well-formed XML.
0x1A04: Smart Component file does not exist or is not readable: <smart-component filename>.
These issues might occur due to either erroneous FMT installation or unexpected manual deletion
of or tampering with FMT-installed files.
Suggested action
Reinstall the FMT RPM file. The FMT RPM file is bundled with QR DVD and can be located at the
following directory:
/usr/local/ibrix/installation/ibrix/
distrib/ibrix/RHEL5/x86_64/platform_rpms/<platform>
Use the following command to reinstall the FMT RPM file:
# rpm ivh force <FMT rpm>
Any operation failed with Error: 0x1A0C
Related error messages
Error Message: Internal error - Missing file/directory /opt/hp/platform/bin/hpsp_chassis_info
Error Message: Internal error - Missing file/directory /opt/hp/platform/bin/hpsp_cluster_info
Error Message: Internal error - Missing file/directory /opt/hp/platform/bin/hpsp_server_ctrl
Error Message: Internal error - Missing file/directory /opt/hp/platform/bin/hpsp_srvid
These issues might occur due to erroneous installation of FMT-dependent tools or unexpected manual
deletion of or tampering with installed files.
Suggested action
Reinstall the platform tools RPM. The platform tools RPM bundled with QR DVD can be located at
the /usr/local/ibrix/installation/ibrix/distrib/ibrix/RHEL5/x86_64/
platform_rpms/PSP/ directory.
Use the following command to reinstall the platform tools RPM file:
# rpm ivh force /usr/local/ibrix/installation/ibrix/distrib/ibrix/
RHEL5/x86_64/platform_rpms/PSP/hpsp-platform-tools-<version>.x86_64.rpm
StoreAll 9730/IBRIX X9720 chassis components
SAS switch discovery/flash recommendation/flash failure with one of the errors:
0x105E, 0x1047, 0x1A22
Error Messages:
0x105E - Flash Failed for SAS_SWITCH_BAY_<SAS interconnect bay number>: Unable to retrieve
peer info (<peer sas switch interconnect bay no>)
78 Troubleshooting