HP Storage Platform Firmware Management Tool for StoreAll User Guide

It is important not to run the flash operation for the same component for which a flash operation
is already in progress.
3. Issue a flash recommendation operation for the component to see if the flash has succeeded,
by using the command:
# hpsp_fmt fr c <component>
If not, retry the flash operation.
Any Storage component discovery/flash recommendation/flash failed with Error:
0x1A2D
Error Message:One or more of HP Storage controller models are unsupported.
One of the storage controllers might have been pulled out or is not seated properly.
Suggested action
1. Check if the controllers are seated properly.
2. If not, pull out the controller, reseat the controller in its correct position, and retry the operation.
90 Troubleshooting