c. Press the Enter key to access the MP. If there is no response, press the MP reset pin on the back
of the MP and try again.
d. Log in to the MP using the default user name and password shown on the screen. The MP Main
Menu is displayed.
3. Enter SL to clear the error logs (CLR).
4. Enter CM to display the Command Menu.
NOTE: Most of the MP commands of the HP Integrity rx8620 are similar to the HP Integrity rx2600
MP commands, but there are some differences. The two MPs for the HP Integrity rx8620 operate in
a master/slave relationship. Only the master MP, which is on Core IO board 0, is assigned an IP
address. Core IO board 0 is always the top Core IO board. The slave MP is used only if the master
MP fails.
5. Enter LC to configure the IP address, subnet mask, and default gateway address for the HP Integrity
rx8620 master MP interfaces; do not configure an IP address for the slave MP.
Gateway address is 172.21.0.16 (default based on 16 nodes)
Subnet mask address is 255.0.0.0
IP addresses are listed in Table 3-20.
Table 3-20 IP Addresses for MP Power Management Devices
26xx ProCurve PortIP AddressNode
172.21.0.15First node after the head node is n15
172.21.0.14Second node after the head node is n14
172.21.0.13Third node after the head node is n13
(. . .)(. . .)
n172.21.0.x
First rx8620 master MP
n-1
N/AFirst rx8620 slave MP
n-2172.21.0.x-2
Second rx8620 master MP
n-3
N/ASecond rx8620 slave MP
See the HP Integrity rx8620–32 Server Installation Guide if you need more information.
6. Enter XD to apply your changes. Enter R to restart the MP.
7. Enter CM to return to the Command Menu.
8. Enter SO to set the MP user name and password. The user name must have a minimum of 6 characters,
and the password must have a minimum of 8 characters. You must set the same user name and
password on every node.
IMPORTANT: The remaining steps in this procedure (setting the network boot option, the boot order,
and console options) must be performed twice, once for each partition on the HP Integrity rx8620
system.
On HP Integrity rx8620 systems, some MP commands, such as CO and PE, prompt you to supply the
partition on which to perform the action.
9. Enter PE (power enable) to turn on power to the cabinet, if it is not already turned on.
10. Enter PE (power enable) to turn on power to the partition.
11. Press Ctrl+b to return to the Main Menu; then enter CO to connect to the console of the partition.
NOTE: If the console stops accepting input from the keyboard, the following message is displayed:
[Read-only - use ^Ecf to attach to console.]
Preparing Individual Nodes 61