HP XC System Software Installation Guide Version 3.1

2: serviceguard
A choice of 'standard' (1) means no improved availability.
Enter the number corresponding to the way to configure availability []: 2
8. Enable Web access to the Nagios monitoring application and create a password for the nagiosadmin
user. This password does not have to match any other password on the system. In this example, the
Nagios service has been configured with improved availability.
Executing C50nagios gconfigure
Availability can be configured for nagios in one of several ways.
The choices are:
1: standard
2: serviceguard
A choice of 'standard' (1) means no improved availability.
Enter the number corresponding to the way to configure availability []: 2
Would you like to enable web based monitoring? ([y]/n) y
Enter the password for the 'nagiosadmin' web user:
New password: your_nagios_password
Re-type new password: your_nagios_password
Adding password for user nagiosadmin
Executing C50nat gconfigure
9. If you configured improved availability for the NAT service, you are prompted to enter an additional
external IP address to use as an external alias:
Availability can be configured for nat in one of several ways.
The choices are:
1: standard
2: serviceguard
A choice of 'standard' (1) means no improved availability.
Enter the number corresponding to the way to configure availability []: 2
Please provide the external IP alias for server n16 []: IP_address
Please provide the external IP alias for server n14 []: IP_address
10. Specify how you want to configure the snmptrapd service if the hardware configuration includes
HP server blade enclosures or if you have defined an mcs.ini file to configure MCS devices.
Enclosures and MCS devices are connected to the Administration Network, so accept the default
responses of Admin and loopback if you want Nagios to generate alerts for critical SNMP traps sent
from either an enclosure or an MCS device.
Enter the letter R to specify External and Interconnect if the system is configured with additional
SNMP-based devices that are connected to either the external or interconnect networks but are not
connected to the Administration Network.
Executing C50supermond gconfigure
Executing C51nagios_monitor gconfigure
Executing C60nis gconfigure
Executing C51nagios_monitor gconfigure
Executing C52snmp_traps gconfigure
Configuring the snmptrapd service for the cluster.
SNMP traps are configured to be received over the following interfaces:
loopback
Admin
Snmptrapd is also configured to listen to the Nagios IP alias.
Enter any additional interfaces over which SNMP traps are to be received:
1) External
2) Interconnect
Use a space-separated list to specify multiple interfaces, for example, 1
3.11 Task 10: Respond to Configuration Questions 73