The following table shows examples of specifying the parameter subtarget and the subinfo
parameters.
Table 44 Examples of using the GetStorageArray command
Command specificationInformation to acquire
GetStorageArray subtarget=LDEV
LDEV information
GetStorageArray
subtarget=LogicalUnit
lusubinfo=Path
Information about paths for logical units
GetStorageArray subtarget=LDEV
ldevsubinfo=VolumeConnection
Mapping information of external volumes for LDEVs
GetStorageArray
subtarget=ArrayGroup
arraygroupsubinfo=LogicalUnit
lusubinfo=LDEV,Path
Information about logical units for parity groups and about
LDEVs and paths for those logical units
GetStorageArray subtarget=Path
pathsubinfo=WWN,HostInfo
Information about paths and WWNs for those paths
GetStorageArray subtarget=Pool
poolsubinfo=LogicalUnit
Information about pools and logical units for those pools
For details about parameters other than the parameter subtarget and the subinfo parameters, see
GetStorageArray (subtarget not specified) on page 122 to GetStorageArray
(subtarget=ReplicationInfo) on page 176.
GetStorageArray (subtarget not specified)
By executing GetStorageArray without specifying the subtarget parameter, you can obtain
basic information about all the storage systems (including SMI-S Enabled storage systems) that are
registered on the Device Manager server.
Format
When obtaining information about all storage systems:
hdvmcli [URL] GetStorageArray [options]
When obtaining information about a storage system (other than an SMI-S Enabled storage system):
hdvmcli [URL] GetStorageArray [options]
serialnum=serial-number model=model
When obtaining information about an SMI-S Enabled storage system:
hdvmcli [URL] GetStorageArray [options]
saobjid=object-ID-of-SMI-S-Enabled-storage-system
Command reference122