HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionStatusParameter name
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Domain ID of the host storage domain
If you omit this parameter, all the host storage domains become
the target. If you specify this parameter, you must also specify the
model and serialnum parameters. This parameter can be
specified in decimal and hexadecimal. If you specify a
hexadecimal number, add the 0x prefix.
The execution results are output in decimal.
If you specify this parameter, you must also specify the port or
portname parameter. If neither is specified, this parameter will
be ignored.
Do not specify domain and domainnickname at the same time.
If they are specified at the same time, an error will occur.
Optional
domain
Nickname of the host storage domain
If you omit this parameter, all the host storage domains become
the target. If you specify this parameter, you must also specify the
model and serialnum parameters.
If you specify this parameter, you must specify the port or
portname parameter. If neither is specified, this parameter will
be ignored.
Do not specify domain and domainnickname at the same time.
If they are specified at the same time, an error will occur.
Optional
domainnickname
Specific information about the host storage domain
The values you can specify are WWN, Path, and FreeLUN. If you
specify multiple values at the same time, separate the values by
commas.
Optional
hsdsubinfo
Number of the port containing the host storage domain
If port and portname are omitted, information about all ports
is displayed. If you specify this parameter, you must also specify
the model and serialnum parameters.
If you specify this parameter, you must specify the domain or
domainnickname parameter. If neither is specified, this
parameter will be ignored.
Do not specify port and portname at the same time. If they are
specified at the same time, an error will occur.
Optional
port
Port name of the host storage domain
If port and portname are omitted, information about all ports
is displayed. If you specify this parameter, you must also specify
the model and serialnum parameters.
If you specify this parameter, you must specify the domain or
domainnickname parameter. If neither is specified, this
parameter will be ignored.
Do not specify port and portname at the same time. If they are
specified at the same time, an error will occur.
Optional
portname
CLI Reference Guide 141