HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

productName=12000
vendor=HP
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=LogicalDKC)
GetStorageArray (subtarget=LogicalDKC) obtains the information about the logical DKC in
one or all storage systems.
Parameters
Table 54 GetStorageArray (subtarget=LogicalDKC) command parameters
DescriptionStatusParameter name
Specify LogicalDKC.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
In this example, the GetStorageArray (subtarget=LogicalDKC) command obtains information
about the logical DKC in a storage system (serial number: 12345, model: XP24000).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_LogicalDKC.log"
subtarget=LogicalDKC model=XP24000 serialnum=12345
Command execution result
RESPONSE:
An instance of StorageArray
objectID=*****
name=XP24000 @10.208.115.221
description=XP24000 (12345) at 10.208.115.221
serialNumber=12345
arrayFamily=XP24K
CLI Reference Guide 147