HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionStatusParameter name
Number of logical units for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of logical units in a specific storage system. Specify the
number of logical units for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Device number of the logical unit
Specify this parameter to acquire information about a particular
logical unit.
For P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
If you specify this parameter, you must also specify the model
and serialnum parameters.
The execution results are output in decimal.
Optional
displayname
Label name of logical units for which information is to be obtained
Specify this parameter to obtain information about logical units
for which a specific label is specified. You can specify only one
label.
If you specify this parameter, you must also specify
lusubinfo=LDEV.
Optional
label
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
objectid
Obtain this value from the execution result of the GetStorageArray (subtarget=Logic-
alUnit) command. Execute this command by specifying only the model and serialnum
parameters, and LogicalUnit for the subtarget parameter. In the execution result of this
command, the required objectID value appears under An instance of LogicalUnit.
Use this objectID value to specify the objectid parameter.
Command execution example
In this example, the GetStorageArray (subtarget=LogicalUnit) command obtains information
about the logical units in a storage system (serial number: 10001, model: XP12000). The information
CLI Reference Guide 151