HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

Parameters
Table 73 RefreshPerformanceData command parameter
DescriptionStatusParameter name
Serial number of the storage system
Optional
#
serialnum
Model of the storage system
Optional
#
model
Parameter used to refresh performance information for all storage
systems
The value you can specify is all, which is not case-sensitive.
Optional
#
option
#
Always specify either the serialnum and model parameters together, or option=all.
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
In this example, the RefreshPerformanceData command refreshes performance information for
a specific storage system.
hdvmcli RefreshPerformanceData -o "D:\logs\RefreshPerformanceData.log"
serialnum=10037 model=R600
Command execution result
RESPONSE:
An instance of PerformanceStatus
arrayType=XP24000
serialNumber=10037
status=SUCCEEDED
RefreshStorageArrays
The RefreshStorageArrays command refreshes the configuration information for all of the storage
systems (including SMI-S Enabled storage systems) that are managed by the Device Manager server
to the most recent information.
Execute this command regularly to keep the Device Manager server database up to date. For storage
systems that are managed by Device Manager, configuration information that is created or modified
from the Remote Console, Remote Web Console, or RAID Manager is added to or updated in the
Device Manager server database each time this command is executed.
CLI Reference Guide 215