HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionAttribute
Indicates whether the value output to threshold2 is the value determined by the
storage system.
If the storage system is P9500 and poolFunction is 5, either of the following
values is output:
0: Value determined by the storage system
1: Value set by the user
This information is unknown or invalid for other cases (-1 is output).
threshold2Mode
Capacity of the pool (KB)
When poolFunction is 3 or 5, this value does not match the total capacity of
the pool volumes because the pool of Snapshot or Thin Provisioning uses a control
area.
capacityInKB
Unused capacity of the pool (KB)
For example, for XP24000/XP20000, when poolFunction is 5, the unused
capacity of the THP pool is output.
freeCapacityInKB
Usage rate of the pool
For example, for XP24000/XP20000, when poolFunction is 5, the usage rate
of the THP pool is output.
usageRate
Number of pool volumes
For example, for XP24000/XP20000, when poolFunction is 5, the number of
THP pool volumes is output.
numberOfPoolVols
Number of virtual volumes assigned to the pool
For example, for XP24000/XP20000, when poolFunction is 5, the number of
THP volumes assigned to the THP pool is output.
numberOfVVols
Total capacity of the virtual volumes assigned to the pool (KB)
For example, for XP24000/XP20000, when poolFunction is 5, the total
capacity of the THP volumes assigned to the THP pool is output.
capacityOfVVolsInKB
CLPR number of the pool
The CLPR number is output for the pool that corresponds to the function type output
to poolFunction.
clprNumber
RAID level (example: RAID6 or RAID1+0)
For P9500, this item is output if the pool is a THP pool.
Unknown is output if any of the following conditions are satisfied:
RAID level is unknown
RAID levels are mixed
RAID configurations with different combinations of data drives and parity drives
are mixed
This information is invalid for other cases.
raidLevel
CLI Reference Guide 349