HP P9000 Tiered Storage Manager Software 7.4.1-00 CLI Reference Guide (TB585-96029, April 2013)

Specifiable characters or valuesOperatorsProperty name
Simplex
P-VOL
S-VOL
=, <>
ContinuousAccessSynchronous
( ContinuousAccessXPSynchronous
)
For GetStorageArray
(subtarget=ArrayGroup) in Device
Manager CLI, specify the value displayed for
the displayName attribute of the
ArrayGroup object.
You can specify the following characters:
A to Z
a to z
0 to 9
Hyphen (-)
Underscore (_)
Period (.)
At sign (@)
Space character
Non-ASCII characters
If the operator is = or <>, commas (,) can be
used to specify multiple
ControllerArrayGroup names. The
maximum number of elements separated by
commas (,) is 100.
No more than 75 bytes can be specified for
each ControllerArrayGroup name.
=, <>,
startsWith,
contains
ControllerArrayGroup
Specify this property in the following format:
[logical-DKC-number:]CU-number:LDEV-number
Specify hexadecimal values that are less than
0x100 and that are separated by colons (:).
A 0 at the beginning of the first value can be
omitted.
The following are specification examples:
When omitting a logical DKC number:
Specify 2:0a or 02:0A.
When specifying a logical DKC number:
Specify 0:02:0a or 00:02:0A.
You can specify a list of values separated by
commas (,) or a range of values separated by
a hyphen (-).
The maximum number of elements separated
by commas (,) is 100.
The range separated by a hyphen (-) can
specify only 1 element.
=ControllerDeviceNumber
Yes
No
=
CVS
#1
CLI Reference Guide 43