HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

CAUTION:
If the GUI displays a warning message, manually refresh the corresponding storage system information.
You can also specify the settings so that information in the database is automatically updated in case
a user forgets to perform a manual refresh after changing the storage system configuration. To do
so, set up the following properties:
server.dispatcher.daemon.autoSynchro.doRefresh property
server.dispatcher.daemon.autoSynchro.type property
The Device Manager server cannot detect the following configuration change performed on P9500
or XP24000/XP20000:
Creating, changing, or deleting copy pairs
Changing the status of an LDEV (such as Normal, Blocked, or Copying)
Changing the access attribute of an LDEV (such as Read/Write, Read Only, or Protect)
The Device Manager server treats the following operations as configuration changes of P9500 or
XP24000/XP20000:
Restarting SVP
Refreshing the configuration information of P9500 or XP24000/XP20000 displayed in Remote
Web Console.
Switching the SVP in a cluster configuration from the executing node to the standby node, or vice
versa.
Turning on the DKC
server.dispatcher.daemon.autoSynchro.doRefresh
This property specifies whether to automatically refresh the information of P9500 or XP24000/XP20000
in the database if the Device Manager server detects that the configuration of the P9500 or
XP24000/XP20000 has changed.
If true is specified for this property and a user does not perform a manual refresh after the Device
Manager server detects a change, the information of P9500 or XP24000/XP20000 in the database
is automatically refreshed at the interval specified in the
server.dispatcher.daemon.autoSynchro.type property. If false is specified, the database
is not automatically refreshed.
Default: true
CAUTION:
If you specify true, only the information about the P9500 or XP24000/XP20000 is updated in the
database. The information in the configuration file of a host that recognizes the command device of
P9500 or XP24000/XP20000 is not updated in the database.
server.dispatcher.daemon.autoSynchro.type
This property specifies the interval at which storage system information in the database is automatically
updated (refreshed) using one of the following values:
Device Manager server properties324