HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)

8. Use the cluster management application to enable failover of the resource group.
Change the settings of the resources listed below.
HP StorageWorks XP Tiered Storage Manager
DeviceManagerServer
HCS Device Manager Web Service
HBase 64 Storage Mgmt Web Service
HBase 64 Storage Mgmt Common Service
HiRDBClusterService _HD1
HP XP7 Command View Advanced Edition product resources other than the above
Right-click the resource names, and then from the Policies tab under Properties, select the following
items:
If resource fails, attempt restart on current node
If restart is unsuccessful, fail over all resources in this Role (or If restart unsuccessful, fail over
all resources in this service or application)
9. In the cluster management application, bring online the resource group in which the HP XP7
Command View Advanced Edition product services are registered.
Related topics
Starting the HP XP7 Command View Advanced Edition services, page 165
Stopping the HP XP7 Command View Advanced Edition services, page 166
Restoring databases
If an error occurs with a database, use the following methods, depending on the situation, to restore
the database:
When a database inconsistency occurs:
The database can be restored by using a database that has been backed up via the hcm-
ds64backups command.
All of the following must be same between the management server when the database was backed
up and the management server when the database is restored:
Type, version, and revision of the installed HP XP7 Command View Advanced Edition products
Installation destination of the HP XP7 Command View Advanced Edition products
Installation destination of Common Component
Installation destination of the HP XP7 Command View Advanced Edition product databases
Installation destination of the Common Component database
IP address and host name of the computer
When a database is corrupted:
The database can be restored by using a database exported via the hcmds64dbtrans command.
The type, version, and revision of the installed HP XP7 Command View Advanced Edition products
must be the same between the management server when the database was exported and the
management server when the database is restored.
When the hcmds64dbrepair command is executed, all of the HP XP7 Command View Advanced
Edition databases installed on the management server are forcibly deleted and then replaced by
the exported databases.
Administrator Guide (Web Version) 175