HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)

For HP XP7, P9500 and XP24000/XP20000 storage systems, a numerical value that is a com-
bination of the LDKC, CU, and LDEV numbers (LDKC x 65536 + CU x 256 + LDEV) is output.
For XP1024/XP128, and XP12000/XP10000/SVS200, a numerical value that combines the
CU and LDEV numbers (= CU x 256 + LDEV) is output.
#5:
The virtual volume is created from the Smart pool (associated with Smart pool).
#6:
The replication operation type attribute is represented by the common output name indicated in
Table 105 when it is output.
Table 104 Common output names for storage system models
Applicable storage system modelCommon output name
XP1024/XP128R450
XP12000/XP10000/SVS200R500
XP24000/XP20000R600
P9500R700
HP XP7R800
Table 105 Common output names for replication operation type attributes
Applicable productCommon output name
Business CopyLocal Copy
Continuous Access AsynchronousRemote Copy (Async)
Continuous Access JournalRemote Copy (Jrnl)
Continuous Access SynchronousRemote Copy (Sync)
SnapshotSnapShot
Fast SnapSnapShot (Fast)
Correlation between user operations and Tiered Storage Manager CLI audit log
data
This section describes what audit log data is output as a result of operations that a user performs in
Tiered Storage Manager CLI.
To estimate the user-performed CLI commands by examining the output audit log data:
1. Extract the audit log data output by Tiered Storage Manager (data where the program name is
TSMgr).
Audit log data created by executing CLI commands is output by Tiered Storage Manager and
has the TSM_CLI application identifier information.
When multiple users are accessing Tiered Storage Manager at the same time, you can perform
filtering by the user IDs that are output to subject-identification-information.
HP XP7 Command View Advanced Edition audit logs290