HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 Administrator Guide (Web Version)

CAUTION:
If the GUI displays a warning message, manually refresh the corresponding storage system inform-
ation.
You can also specify the settings so that information in the database is automatically updated in
case a user forgets to perform a manual refresh after changing the storage system configuration.
To do so, set up the following properties:
server.dispatcher.daemon.autoSynchro.doRefresh property
server.dispatcher.daemon.autoSynchro.type property
The Device Manager server cannot detect the following configuration changes:
- Changes in the LDEV status (such as normal, blocked, or being copied).
- Creating, changing, or deleting copy pairs
In addition, the Device Manager server cannot detect changes to the access attribute of LDEVs
(such as Read/Write, Read Only, or Protect) that are performed on XP24000/XP20000.
In the Device Manager server the configurations of storage system are treated as changed for the
following triggers:
- Restarting SVP
- Refreshing the configuration information of storage system displayed in Remote Web Console.
- Switching the SVP in a cluster configuration from the executing node to the standby node, or
vice versa.
- Turning on the DKC
- The configuration of a THP/Smart pool is changed
#
The configuration of the Snapshot data pool or the Fast Snap data pool is changed
#
#:
For P9500, if you specify false for the server.dispatcher.daemon.configUpdate.de-
tection.variable.enabled property, you can prevent a warning message from being
displayed in the Device Manager GUI when the pool configuration is changed.
Related topics
server.dispatcher.daemon.autoSynchro.doRefresh, page 359
server.dispatcher.daemon.autoSynchro.type, page 360
server.dispatcher.daemon.configUpdate.detection.variable.enabled, page 361
server.dispatcher.daemon.autoSynchro.doRefresh
Specify whether to automatically refresh the storage system information in the database if the Device
Manager server detects that the configuration of a P9500 or XP24000/XP20000 storage system has
changed.
If true is specified for this property and a user does not perform a manual refresh after the Device
Manager server detects a change, the information of P9500 or XP24000/XP20000 in the database
is automatically refreshed at the interval specified in the
server.dispatcher.daemon.autoSynchro.type property. If false is specified, the database
is not automatically refreshed.
Default: true
Administrator Guide (Web Version) 359