HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 Administrator Guide (Web Version)

NOTE:
If you changed the value of this property, the following settings must be performed:
Use the netsh command to reset the firewall exemptions (when the value of the hdc.ssl.secure
property is 2 or 3).
Set the same value as the hdc.rmiserver property of the Device Manager server (when SSL
communication is used by Host Data Collector and the Device Manager server).
Related topics
Registering an exception for the Host Data Collector service (for SSL communication), page 273
hdc.rmiserver, page 370
hdc.ssl.secure, page 396
hdc.common.https.serverPort
Specify the SSL communication port number of the class loader.
Specifiable range: 1 to 65535.
Default: 22106
NOTE:
If you changed the value of this property, the following settings must be performed:
Use the netsh command to reset the firewall exemptions (when the value of the hdc.ssl.secure
property is 2 or 3).
Set the same value as the hdc.classloader property of the Device Manager server (when SSL
communication is used by Host Data Collector and the Device Manager server).
Related topics
Registering an exception for the Host Data Collector service (for SSL communication), page 273
hdc.classloader, page 371
hdc.ssl.secure, page 396
hdc.service.rmi.registryIPAddress
If the machine that is running Host Data Collector has multiple IP addresses, specify the IP address to
be used for communication with the Device Manager server.
For the IP address, you can use either an IPv4 address or IPv6 address.
Make sure that the IP address you specify is the same as the value specified for the following properties
in the hostdatacollectors.properties file on the Device Manager server:
hdc.rmiregistry
hdc.rmiserver
hdc.classloader
Administrator Guide (Web Version) 395