TIP:
After installing Application Agent, if the Copy Controller service or the Common Agent Service is
Disabled, change the setting to Automatic.
The Common Agent Service is used by other agent programs (such as Device Manager Agent). When
you stop Common Agent Service, you should determine whether or not the operation of other agents
is affected.
Setting error logging options for Application Agent
The agent.logger.properties file is used to specify the values of log output-related properties.
The file is stored in the following location:
C:\P9000-Command-View-AE-Common-Agent-Component-installation-folder\agent\
config\
If a value is not specified in the agent.logger.properties file or if the specified value is outside
the specifiable range, the default value is used.
The following tables list the available properties, the types of information logged, and the parameters
that are stored when values are logged.
Table 42 List of properties in the agent.logger.properties file
DescriptionProperty
The output level of the Replication Manager log file. Messages
matching the type are output to the log file.
Specifiable values: One of the three following scenarios: DEBUG
and INFO, WARN,
or ERROR and FATAL.
See Table 43 for a description of the types and Table 44 for a list
of types logged for each level. These values can be entered in any
combination of upper and lower case.
Default value: INFO
agent.logger.loglevel
The maximum number of log files created in Replication Manager.
When the number of log files reaches this value, the existing files
are reused, starting with the oldest file.
Specifiable values: 1 to 20 (files)
Default value: 10
agent.logger.MaxBackupIndex