HP StorageWorks P9000 Command View Advanced Edition Software 7.1.0-00 Release Notes (TB581-96047, October 2011)

23
Automatically generating short file and folder names (Windows)
Make sure that the setting for automatically generating short file and folder names (8.3 format) is
enabled. Also, when installing, use a Windows account that was created when the setting was
enabled.
If these conditions are not satisfied, the install might fail, or Command View Advanced Edition Suite
might not work properly.
Even after the installation is complete, do not change the setting for automatically generating short
names.
To check whether a user was created while the setting for automatically generating short file and
folder names was disabled, execute the following command:
dir /x /a- Windows-system-drive:\Documents and Settings\Windows-account-
name | find /i Local Settings
The following two examples show the command execution results when the setting for automatically
generating short file and folder names was enabled during creation of the user, and the results
when the setting was disabled during creation of the user. If LOCALS~1 is displayed, the user was
created while this setting was enabled.
If the user was created while the setting was enabled:
2010/01/01 18:26 <DIR> LOCALS~1 Local Settings
If the user was created while the setting was disabled:
2010/01/01 18:26 <DIR> Local Settings
Terminal service (Windows)
You cannot execute the Command View Advanced Edition Suite installer as a RemoteApp in the
terminal service of Windows Server 2008 or Windows Server 2008 R2.
The symbolic links (UNIX)
Ensure that the symbolic links indicated in the following table are not set. If any are set, installation
might fail.
Location
/opt
/var/opt
/var/tmp
Under
/opt/CVXPAE #
Under
/var/opt/CVXPAE #
Under
/var/opt/CVXPAE /database #
Under
/var/opt/CVXPAE /database/Base #
Under
/var/opt/CVXPAE/database/DeviceManager#
Under