HP StorageWorks P9000 Tiered Storage Manager Software 7.1.1 CLI Reference Guide (TB585-96014, September 2011)

DescriptionItem
The refresh status. This can be any of the following:
NotInitialized
Processing
Success
Failure
Incomplete
(ended without completing refresh)
RefreshRequired
refreshStatus
The date and time when the previous refresh finished. If the previous refresh
has not finished, nothing is displayed.
[lastRefreshedTime]
The serial number of the domain controller
[controllerSerialNum-
ber]
The model name displayed on the domain controller
[controllerDisplayMod-
el]
The name of the domain controller
[controllerName]
The logical DKC number of the domain controller. If the storage system is not
HP P9500 or XP24000/XP20000, nothing is displayed.
[logicalDKCNumber]
A description of the storage domain
[description]
Legend:
[ ]: Indicates output only when either the -d or the --detail option is specified.
Table 14 Items output by the GetStorageDomains command (ErrorInfo instance)
DescriptionItem
An error message
message
NOTE:
Unknown is output for some output items when the refresh status is NotInitialized, Processing,
or Failure.
Example and execution results
Command execution example:
In this example, detailed information is obtained for the storage domains MegaTechXP12000-
Primary and MegaTechXP12000-Secondary.
htsmcli GetStorageDomains --detail
name="MegaTechXP12000-Primary,MegaTechXP12000-Secondary"
Execution results:
CLI Reference Guide 59