HP XP P9000 Command View Advanced Edition Suite Software 7.6.1-00 CLI Reference Guide

threshold=-1
systemDisk=0
encrypted=-1
tieringPolicy=-1
resourcePartitionUnitID=-1
List of 1 VolumeConnection elements:
An instance of VolumeConnection
objectid=*****
mappedArrayType=XP12000
mappedSerialNumber=10001
mappedDevNum=0
displayMappedDevNum=00:00
externalArrayType=XP12000
externalSerialNumber=10002
externalDevNum=150
displayExternalDevNum=00:96
externalVolumeName=0096
productName=12000
vendor=HP
*****: The values are encoded by the CLI.
GetStorageArray (subtarget=LogicalDKC)
GetStorageArray (subtarget=LogicalDKC) obtains the information about the logical DKC in
one or all storage systems.
Parameters
Table 56 GetStorageArray (subtarget=LogicalDKC) command parameters
DescriptionStatusParameter name
Specify LogicalDKC.
Required
subtarget
Serial number of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
serialnum
Model of the storage system
If you omit this parameter, all the storage systems become the
target.
Optional
model
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example
In this example, the GetStorageArray (subtarget=LogicalDKC) command obtains information
about the logical DKC in a storage system (serial number: 12345, model: XP24000).
CLI Reference Guide 161